Modular Valves
D
D-72
Check Modular Valve
50 to 300
rr
/min
25,35MPa
Features
qThis modular valve is a check valve
that prevents reverse-flow.
wThe 01, 03, 04 sizes include types
that can also be used as suction and
differential circuits.
eMaximum Operating Pressure: 25,
35MPa {255, 357kgf/cm
2
}
Specifications
Model No.
Nominal Diameter
(Size)
Maximum Working
Pressure
MPa{kgf/cm
2
}
Maximum Flow Rate
r/min
Cracking pressure
MPa{kgf/cm
2
}
Weight
kg
Gasket Surface
Dimensions
OC-G01-P1-20
P2
P3
1/8 25{255} 50
0.04{0.4}
0.35{3.6}
0.50{5.1}
1.0
ISO 4401-03-02-0-94
OC-G01-T1-20
T2
T3
0.04{0.4}
0.35{3.6}
0.50{5.1}
1.0
OC-G01-A1-21
A2
A3
0.04{0.4}
0.35{3.6}
0.50{5.1}
1.2
OC-G01-AP1-20
AP2
AP3
0.04{0.4}
0.35{3.6}
0.50{5.1}
1.0
OCV-G01-W-20
0.015{0.15}
1.0
OC-G03-P1-J50
P2
P3
3/8 25{255} 100
0.04{0.4}
0.35{3.6}
0.50{5.1}
2.7
ISO 4401-05-04-0-94
OC-G03-T1-J50
T2
T3
0.04{0.4}
0.35{3.6}
0.50{5.1}
2.7
OC-G03-A1-J50
A2
A3
0.04{0.4}
0.35{3.6}
0.50{5.1}
2.7
OC-G03-AP1-J50
AP2
AP3
0.04{0.4}
0.35{3.6}
0.50{5.1}
2.7
OCV-G03-W-J50
0.015{0.15}
3.5
OCH-G04-P1-10
P2
P3
1/2 35{357} 300
0.04{0.4}
0.35{3.6}
0.50{5.1}
4.5
ISO 4401-07-06-0-94
OCH-G04-T1-10
T2
T3
0.04{0.4}
0.35{3.6}
0.50{5.1}
6.5
OCH-G04-A1-10
A2
A3
0.04{0.4}
0.35{3.6}
0.50{5.1}
4.5
OCH-G04-AP1-10
AP2
AP3
0.04{0.4}
0.35{3.6}
0.50{5.1}
4.5
OVH-G04-W-10
0.01{0.1}
6.5
zDifferential circuit can be easily config-
ured at P
→
B by attaching OC-G**-A*
above the OC-G**-AP* on the sub-
plate. (See the figure to the right.)
xNote that a sub plate and installa-
tion bolts are not included. See
pages D-90 through D-95 if these
items are required.
c04 series modular valves do not
have an L (DR
2) drain port, so they
cannot be used in combination with
pressure center type solenoid
valves (D).
¡Handling